Micro Button Load Cell

Description

Applied Measurements CDFT micro button load cell is designed for compression measurement applications where the absolute minimum of space is available for transducer mounting.

With capacities from 10N to 250N available and measuring just 9mm in diameter and 2.9mm in height, the CDFT is the smallest standard button load cell that we offer.  If you need to measure lower or higher forces, the CDFM3 miniature button load cell is available in capacities from 0-100N right up 0-20kN and is slightly larger at 30mm diameter and 12mm in height.

Applied Measurements CDFT micro button load cell is ideal for retro-fitment and is ideal to use in robotics and effectors, hoist and winch loads, micro-component assembly tools and machinery, keyboard button and telephone control and mechanical switches.

Product Dimensions

micro button load cell CDFT outline dimension drawing

Wiring Details

WireDesignation
Red+ve excitation
Blue-ve excitation
Green+ve signal
Yellow-ve signal
ScreenTo ground – not connected to load cell body

Features

  • Capacities: 0-10N up to 0-250N
  • Ø9mm and 2.9mm Height
  • Environmental Protection: IP53
  • Accuracy: <±0.25%/RC
  • Integral Load Button

Spesification

Rated CapacityN0-10, 0-25, 0-50, 0-100, 0-200, 0-250
Operating ModesCompression Only
Sensitivity (RO)mV/V (nominal)10N = 0.4 25N = 0.5 50N = 1.0 100N = 2.0 200N = 2.0 250N = 2.0
Zero Balance/Offset±%/Rated Output<1.0
Non-Linearity±%/Rated Output<0.25
Hysteresis%/Rated Output<0.25
Repeatability%/Rated Output<0.1
Temperature Effect on Zero±%/Rated Output/ ˚C<0.01
Temperature Effect on Sensitivity±%/Applied Load/ ˚C<0.02
Input ResistanceOhms1000 nominal
Output ResistanceOhms1000 nominal
Insulation ResistanceMegohms>5000 @ 50Vdc
Excitation VoltageVolts AC or DC5 recommended (2-10 acceptable)
Operating Temperature Range˚C-40 to +125 (cell only)
Compensated Temperature Range˚C0 to +100
Storage Temperature Range˚C-40 to +125
Safe Overload% of Rated Capacity150
Ultimate Overload% of Rated Capacity300
Deflection @ Rated Capacitymm<0.02
Fundamental Resonant Frequency*kHz>4
IP Rating (Environmental Protection)IP53
Weightgrams~2 (excluding cable)
Fatigue Life108 cycles typical (109 cycles on fatigue-rated version)
Cable Length (as standard)metres2 (1.5m to compensation module + 0.5m tail)
Cable TypeØ1.35 screened PTFE from cell, Ø3.3 screened PVC from compensation module
Construction MaterialsStainless Steel
Resolution1 part in 250,000 (with appropriate instrumentation)
*The resonant frequency is calculated with the body of the load cell attached to a large plate, ensuring that only the sensing element oscillates. This is vital to achieve the highest natural frequency and subsequent frequency response.