Dome Top Column Load Cell

Description

Applied Measurements CCDDT dome top column load cell is designed to make compression load measurements in general use applications or in permanent outdoor installations.  Thanks to its stainless steel construction and IP67 dust-tight and immersion protection it is suitable for harsh environments.

Further applications include hydraulic press calibration, pile force measurement, jack force measurement, centre of gravity measurement systems and structural proof testing. Verification standard versions are available which are suitable for use in laboratories, please see our 0.1% higher accuracy column load cell.

Standard capacities for the Applied Measurements CCDDT dome top column load cell range from 2 tonnes up to 1000 tonnes, with higher capacity versions available on request.

Capacities of 200te and above are supplied with welded carry handles as standard, included in the price. Optional welded carry handles are available for 50te and 100te only, if required.

The dome top column load cell design can be readily modified to provide higher integrity where environmental conditions are particularly arduous such as in marine and offshore applications.  IP68 fully submersible versions can be offered where such conditions prevail.  It is also possible to manufacture low-height versions if space is at a premium.

Product Dimensions (mm)

CCDDT Outline
MODEL
Capacity (t)
H
ØD
T
S
ØB
Weight (kg)
Resolution (t)
Deflection at RC (mm,nominal)
CCDDT
2
41
31
M3
5
20
1
0.002
0.05
CCDDT
5
41
31
M3
5
20
10.0050.05
CCDDT107550M48342.50.010.10
CCDDT
25
75
50
M4
8
34
2.50.020.10
CCDDT
50
103
88
M4
10
50
6.50.050.12
CCDDT
100
153
100
M5
12
70
110.10.18
CCDDT
200
180
125
M6
n/a
78
190.20.21
CCDDT
300
185
138
n/a
n/a
n/a
210.50.21
CCDDT
500
250
165
n/a
n/a
n/a
420.50.30
CCDDT
750
350
198
n/a
n/a
n/a
851.00.41
CCDDT
1000
400
276
n/a
n/a
n/a
2201.00.46

Wiring Details

WireDesignation
Red+ve excitation
Blue-ve excitation
Green+ve signal
Yellow-ve signal
ScreenTo ground – not connected to load cell body

Features

  • Capacities: 0-2te up to 0-1000te
  • Output: 1.5mV/V
  • Sealed to IP67 (IP68 submersible versions available)
  • Stainless Steel Construction
  • Optional Amplifier Output & Integral Connector
  • Can be Supplied with Loading Cap & Mounting Base

Spesification

Rated Capacity (RC)tonnes0-2, 0-5, 0-10, 0-25, 0-50, 0-100, 0-200, 0-300, 0-500, 0-750, 0-1000
Operating ModesCompression Only
Sensitivity (RO)mV/V1.5 nominal
Zero Balance/Offset±%/Rated Output<1 typical
Non-Linearity±%/Rated Load<0.25 typical
Hysteresis±%/Rated Output<0.25 typical
Non-Repeatability±%/Rated Load<0.05
Temperature Effect on Zero±%/Rated Load / °C<0.01
Temperature Effect on Span±%/Rated Load / °C<0.01
Bridge ResistanceOhms700 (2 - 50te) | 1400 (100 - 1000te)
Insulation ResistanceMegohms @ 500Vdc>500
Excitation VoltageVolts AC or DC10 recommended (2 - 15 acceptable)
Operating Temperature Range°C-20 to +70
Compensated Temperature Range°C-10 to +50
Storage Temperature Range°C-20 to +70
Safe Overload% of Rated Load150
Ultimate Overload% of Rated Load300
Deflection @ Rated CapacitymmSee dimensions table
IP Rating (Environmental Protection)IP67
Weight (exc cable)See dimensions table
Fatigue LifeFull-Range Cycles108 cycles typical (109 cycles on fatigue-rated version)
Cable Length as Standardmetres5
Cable Type4-core screen, PUR sheath
Construction MaterialStainless Steel
Resolution1 part in 250,000 (with appropriate instrumentation)

Reviews

There are no reviews yet.

Be the first to review “Dome Top Column Load Cell”