EM-5 Low Emission Flue Gas Analyzer

Description

EM-5 flue gas analyzer (low emission monitoring) is independently developed by Hangzhou Zetian Technology Co., Ltd., based on years of experience in research and development of flue gas analyzer, combined with the field practice of nearly ten thousand successful application cases. A number of techniques of the flue gas analyzer (standard form) are upgraded (many times return room to increase gas absorption optical path, and higher accuracy of spectrometer, convection heat transfer core module temperature control, etc.) . The analyzer is based on DOAS and chemometric algorithms (PLS) , able to measure concentration of gases including SO2 , NO2, NO, O2 , NH3, Cl2, O3, H2S, CH3I, etc. It has features of high measure accuracy, outstanding reliability, fast response time and wide applicable scope. All indexes reach or exceed those of domestic & foreign similar products, and fully qualify measurement technology index of low emission monitoring occasions.

Technical Principle

EM-5 flue gas analyzer (low emission monitoring) uses the UV DOAS technology.Its optical technology platform consists of light source, multiple return gas chamber, optical and spectroscopic (including diaphragm, holographic grating, linear array detector) and other optical components. As shown in figure. Ultraviolet light is sent by the photosource through the optical window into the gas chamber (optical path 1 meters), and absorbed by the sample gas flow through the gas chamber. The light carrying sample absorption information gathers through lens coupled into the fiber and then transmits through the optical fiber into the spectrometer. Afterlight splitting and photovoltaic conversion, absorption spectrum is obtained and analyzed to calculate the concentration of the related components in gas.

Product Features

High measurement accuracy

  • Ultraviolet has no moisture absorption, undisturbed by moisture and dust
  • No cross interference between the gas being measured (see table 1)
  • NO and NO2 can be measured at the same time, dispense with converter.
  • Low detection limit.

​High reliability

  • Multiple return gas chamber + DOAS + PLS technology,
  • Small amount of zero drift and span drift
  • Modular design
  • No optical moving parts and no vibration influence
  • Strong gas cell, low cost
  • Spectrum automatic adjustment technology, long free maintenance cycle
  • Light source adopts the pulse source, the service life is 10 years

Spesification

Measuring TechniqueDOAS(SO2, NOx),Electrochemistry(O2)
Measuring Range0-100-300ppm (SO2 , NOx),0-25%(O2)
Linearity Error≤±1% F.S.
Repeatability≤±0.5% F.S.
Zero Drifting≤±2% F.S./7d
Measuring Range Drift≤±2% F.S./ 7d
Response Time< 10s( T90 )
Warm-up TimeNone
Relay Output14
Binary Input6
Analog Output4×4 -20mA
Analog Input2×4 -20mA
Digital CommunicationRS232/ RS485 /GPRS
Enclosure RatingIP65
Ambient Temperature-10ºC~40ºC
Ambient Humidity0% Rh~95%Rh

Features

  • Multi-return gas chamber
  • Low detection limit and temperature-drift
  • Getting NOx by directly measuring NO and NO without NO →NO2 converter
  • No interference of particulate matter, moisture and other factors
  • No optical moving parts, high reliability, no interference to the measurement by field

Application

Wide application scope
  • Titanium white production process
  • Sulfur recovery process
  • Natural gas purification process
  • Methyl iodide analysis for the coal chemical industry.
  • On-line air monitoring.
  • Coal-fired power plants.
  • Cement plant.
  • Industrial furnaces.
  • The desulfurization process monitoring.
  • Denitration process monitoring
  • Incinerators

Reviews

There are no reviews yet.

Be the first to review “EM-5 Low Emission Flue Gas Analyzer”

Your email address will not be published. Required fields are marked *