Standard | 1 PNP contact |
Options | 2 independent PNP contacts
4 independent PNP contacts (possible with M12x1, 8-pin for 4-20mA/3-wire;
0-10V/3-wire on request) |
Max. switching current | 4-20mA / 2 and 3 wire: contact rating 125mA, short-circuit resistant;Vswitch = Vs - 2V
0-10V / 3-wire: contact rating 125mA, short-circuit resistant |
Accuracy of contacts 3 | ≤ ± 0.5% FSO |
Repeatability | ≤ ± 0.2% FSO |
Switching frequency | max. 10Hz |
Switching cycles | >100 x 106 |
Delay time | 0-100 sec |
2max. 1 contact for 2-wire current signal with plug ISO 4400 as well as 2-wire current signal with IS-protection
No contact possible with 3-wire in combination with plug ISO 4400. | |
Analogue Output (optionally) / Supply | |
2-wire current signal | 4-20mA / Vs = 13-36Vdc
permissible load: Rmax = [(Vs - Vs min / 0.02 A] Ω response time: <10 msec |
2-wire current signal with IS-protection | 4-20 mA / VS = 15-28 Vdc
permissible load: Rmax = [(VS – VS min) / 0.02 A] Ω response time: < 10 msec |
3-wire current signal | 4-20 mA / VS = 19-30 Vdc adjustable (turn-down of span 1:5) 4 permissible load: Rmax = 500 Ω response time: < 0.5 sec |
3-wire voltage signal | 0-10 V / VS = 15-36 Vdc
permissible load: Rmin = 10 kΩ response time: < 3 msec |
Without analogue output | VS = 15-36 Vdc |
Accuracy 3 | ≤ ± 0.5% FSO |
3 accuracy according to IEC 60770 – limit point adjustment (non-linearity, hysteresis, repeatability) 4 with turn-down of span the analogue signal is adjusted automatically to the new measuring range | |
Thermal effects (Offset and Span) / Permissible temperatures | |
Thermal error | ≤ ± 0.2 % FSO / 10 K |
In compensated range | -25-85 °C |
Permissible temperatures 5 | medium: -40 ... 125 °C electronics / environment: -40 ... 85 °C
storage: -40 ... 100 °C |
5 for pressure port in PVDF the medium temperature is -30 … 60 °C | |
Electrical Protection | |
Short-circuit protection | permanent |
Reverse polarity protection | no damage, but also no function |
Electromagnetic compatibility | emission and immunity according to EN 61326 |
Mechanical stability | |
Vibration | 10 g RMS (25 ... 2000 Hz) according to DIN EN 60068-2-6 |
Shock | 500 g / 1 msec according to DIN EN 60068-2-27 |
Materials | |
Pressure port / housing | standard = stainless steel 1.4404
option for G1/2" open port (up to 60 bar): pressure port: PVDF; housing: stainless steel 1.4404
options for G3/4" flush (0.6 bar ≤ pn ≤ 25 bar): pressure port: PVDF; housing: PVDF |
Display housing | PA6.6, polycarbonate |
Seals (media wetted) | standard: FKM
option: EPDM (pn ≤ 160bar)
others on request |
Diaphragm | ceramics Al2O3 96% |
Media wetted parts | pressure port, seals, diaphragm |
Explosion protection (only for 4 … 20 mA / 2-wire) | |
Approval AX14-DS 201 | IBExU 06 ATEX 1050 X
zone 1: II 2G Ex ia IIC T4 Gb (connector) / II 2G Ex ia IIB T4 Gb (cable) |
Safety tech. maximum values | Ui = 28 V, Ii = 93 mA, Pi = 660 mW, C ≈ 0 nF, Li ≈ 0 µH |
Max. switching current 6 | 70 mA |
Permissible temperatures for
environment | -25 ... 70 °C |
Connecting cables (by factory) | cable capacitance: signal line/shield also signal line/signal line: 100 pF/m cable inductance: signal line/shield also signal line/signal line: 1 µH/m |
6 the real switching current in the application depends on the power supply unit | |
Miscellaneous | |
Display | 4-digit, red 7-segment-LED display, digit height 7 mm, range of indication -1999 ... +9999; accuracy 0.1 % ± 1 digit; digital damping 0.3 … 30 sec (programmable);
measured value update 0.0 … 10 sec (programmable) |
Option oxygen application 7 | for pN ≤ 25 bar: O-ring in FKM Vi 567 (with BAM-approval); permissible maximum values are 25 bar / 150° C |
Current consumption (without contacts) | 2-wire signal output current: max. 25 mA
3-wire signal output current: approx. 45 mA + signal current 3-wire signal output voltage: approx. 45 mA |
Ingress protection | IP 65 |
Installation position | any |
Weight | approx. 200g |
Operational life | 100 million load cycles |
CE-conformity | EMC Directive: 2014/30/EU Pressure Equipment Directive: 2014/68/EU (module A) 8 |
ATEX Directive | 2014/34/EU |
7 not possible with flush pressure ports 8 this directive is only valid for devices with maximum permissible overpressure > 200 bar | |